FS-QS-1010-XXXX FS-QS-1011-XXXX
QuickServer BAS – Cost-effective gateway built on proven FieldServer platform
QuickServer is a high-performance, fully-configurable, cost-effective Building Automation gateway for integrators to easily interface devices to networks in commercial buildings, industrial plants and campuses.
Two QuickServer Designs
FS-QS-1010 is BTL Marked and it includes two serial ports (up to 115K baud) and one Ethernet port (10/100 RJ45). This allows it to communicate serial to serial, serial to Ethernet or Ethernet to Ethernet.
FS-QS-1011 includes one serial port (up to 115K baud), one Ethernet port (10/100 RJ45) and one FTT-10 LonWorks port. This allow s it to communicate serial to serial, serial to Ethernet, Ethernet to Ethernet, serial to LonWorks or Ethernet to LonWorks.
The part number structure for the QuickServer is FS-QS-101X-XXXX. The XXXX indicates the specific model of QuickServer, indicating the drivers pre-loaded.
The user can preselect two BAS drivers (serial, Ethernet and/or LonWorks) to be loaded on the QuickServer at no extra charge. Additional drivers are available at extra costs.
Key Features:
- Multi-configuration capability; specific configurations selectable via DIP switches or software.
- Ability to interface up to 250 points of common BAS protocols.
- Same firmware as our industry proven devices.
- BACnet COV support for fast data communication while reducing traffic over a BACnet network
- Capacity of 250 LonWorks network variables – almost 5 times more than competition – FS-QS-1011 Series
- Flat panel mount standard, DIN rail mount option
- Free BACnet Explorer worth $595 with purchase that include a BACnet driver.
QuickServer can configure a combination of drivers such as Modbus RTU, Modbus TCP, BACnet/IP, BACnet MS/TP, LonWorks, JCI Metasys N2 and SNMP.
Simply select a model in the chart below:
| BACnet/IP |
BACnet MS/TP |
Modbus TCP | Modbus RTU | JCI Metasys N2 | LonWorks | SNMP | |
| BACnet/IP |
|
FS-QS-1010-0285 | FS-QS-1010-0237 | FS-QS-1010-0104 | FS-QS-1010-0122 | FS-QS-1011-0131 | FS-QS-1010-0333 |
| BACnet MS/TP | FS-QS-1010-0285 |
|
FS-QS-1010-0419 | FS-QS-1010-0367 | FS-QS-1010-0309 | N/A | FS-QS-1010-0694 |
| Modbus TCP | FS-QS-1010-0237 |
|
FS-QS-1010-0030 | FS-QS-1010-0117 | FS-QS-1011-0154 | FS-QS-1010-0248 | |
| Modbus RTU | FS-QS-1010-0104 | FS-QS-1010-0367 |
|
FS-QS-1010-0038 | FS-QS-1011-0085 | - | |
| JCI Metasys N2 | FS-QS-1010-0122 | FS-QS-1010-0309 | FS-QS-1010-0117 | FS-QS-1010-0038 |
|
FS-QS-1011-0097 | FS-QS-1010-0150 |
| LonWorks | FS-QS-1011-0131 | N/A | FS-QS-1011-0154 | FS-QS-1011-0085 | FS-QS-1011-0097 |
|
FS-QS-1011-0337 |
| SNMP | FS-QS-1010-0333 | FS-QS-1010-0694 | FS-QS-1010-0248 | - | FS-QS-1010-0150 | FS-QS-1011-0337 |
|
Connections:
Metasys® as used in this document is a trademark of Johnson Controls, Inc.



